WebJan 1, 1992 · @article{osti_7235675, title = {A flowing afterglow study of gas-phase carbene thermochemistry}, author = {Paulino, J A}, abstractNote = {The research discussed in this thesis pertains to the thermochemistry of carbenes, and the structure and reactivity of gas-phase halogenated carbanions. The heats of formation of several carbenes have … Webafterglow: [noun] a glow remaining where a light has disappeared.
Flowing afterglow
Did you know?
WebMay 4, 2006 · We present the optimization of a sterilization process with a N 2 flowing afterglow post-discharge. First we study the inactivation of bacteria (E. coli) submitted to … WebApr 20, 2024 · We describe the plasma chemistry in a helium flowing atmospheric pressure afterglow (FAPA) used for analytical spectrometry, by means of a quasi-one-dimensional (1D) plasma chemical kinetics model. We study the effect of typical impurities present in the feed gas, as well as the afterglow in ambient humid air. The model provides the species …
WebAug 31, 1998 · Flowing afterglow and selected ion flow tube studies of thermal energy electron transfer reactions of sulfur dioxide provide a bracket of the electron affinity of SO 2: 0.744 eV WebThe observed pressure dependences indicate that the recombination process in H3 + dominated plasma can at higher pressure (order of several hundreds pascals) proceeds via a three-body mechanism. Recombination of H3 + ions with electrons was studied in Flowing Afterglow (FALP) experiment at T = 250 K and buffer gas pressure 1500-1600 Pa. In …
WebJun 8, 2024 · Flowing atmospheric-pressure afterglow plasma gas flow rate The signal dependence on the plasma gas flow rate was also studied ( Fig. 3 b). Regarding the gas-phase analyte injection, 2,6-DTBP, there is a considerable increase (around 11 times) in signal intensity as the plasma gas flow rate rises from 100 to 300 mL min −1 , that is … WebFeb 1, 2015 · The flowing afterglow technique incorporates several valuable features that allowed it to revolutionize studies of ion chemistry: (1) The quadrupole mass filter provides definitive identification of the reactant and product ions. (2) The ion formation and reaction regions are spatially and temporally separated. The reactant ions are ...
WebOct 28, 2013 · In this work, the reaction kinetics in argon flowing afterglow with nitrogen addition was studied by optical emission spectroscopy. The DC flowing post-discharge in pure argon was created in quartz tube at the total gas pressure of 1000 Pa and discharge power of 60 W. The nitrogen was added into the afterglow at the distance of 9 cm …
WebApr 6, 2016 · The flowing configuration of argon DC discharge with oxygen admixture was used for this experimental study. The experimental set-up was already used for our previous studies of argon afterglow with nitrogen admixture [] and nitrogen afterglow with mercury vapor admixture [].A simplified schematic drawing of the experimental set-up is given in … canada kids learning tubeWebMay 4, 2006 · We present the optimization of a sterilization process with a N 2 flowing afterglow post-discharge. First we study the inactivation of bacteria (E. coli) submitted to the post-discharge, and discuss the mechanisms of bacteria inactivation. Then we evaluate the volume repartition of the active species (N atoms produced by plasma discharge) in ... canada kit homes british columbiaA flowing afterglow is an ion source that is used to create ions in a flow of inert gas, typically helium or argon. Flowing afterglow ion sources usually consist of a dielectric discharge that gases are channeled through to be excited and thus made into plasma. Flowing afterglow ion sources can be coupled with a selected-ion flow-tube for selection of reactant ions. When this ion source is coupled with mass spectrometry it is referred to as flowing afterglow mass spectrometry. fisher a412-20WebAbstract. The experimental technology of the flowing afterglow technique, including data analysis procedures, has very recently been described in great detail. (1) The present discussion will center on some recent results and their implications for increasing our understanding of ion-neutral reaction processes. fisher a41WebJun 28, 2000 · The flowing afterglow of a microwave discharge can be used to efficiently inactivate bacterial spores. We have conducted a parametric study of the operating … fisher a260WebFlow tube techniques (flowing afterglow, selected ion flow tube) have been used extensively to study ion–molecule reactions and to measure their rate coefficients. There are far fewer studies on the thermal decomposition of gaseous ions. Recently, cluster ions and noncovalent complexes have, however, received considerable attention. ... fisher a412-4WebJanča J, Tálský A, Krčma F, Hochard L and Ricard A (1994) CN chemiluminescence in N2 + CH4 Flowing afterglow at low temperatures, Plasma Chemistry and Plasma Processing, 10.1007/BF01447078, 14:3, ... Thrush B (1968) Atom Reactions in Discharge-Flow Systems Chemische Elementarprozesse, ... canada labour code modified work schedule